Every cover, enclosure and canvas you build is made of panels joined at edges, and every edge needs a decision. How far does the material extend? Is it folded, bound or left raw? Is there a reinforcement? Where does the zipper or the keder sit? You make these decisions on every edge of every project.

A seam type writes one such decision down, once. A seam profile is your shop’s set of seam types.

Without a system, every project starts from scratch. The designer thinks through each edge, sketches the details and writes notes. The sewer reads those notes, sometimes differently than meant. When something goes wrong, nobody is sure whose version was right. Over hundreds of projects a year, that is thousands of hours spent on decisions that should have been made once.

Seam profiles change this. You define each edge once: exactly how it is cut, marked, reinforced and finished. From then on every project uses the same proven seam types. The designer picks from a list instead of working it out again. The sewer sees the same labels and markings on every sewing map. The reinforcements are made for you, trimmed to size, ready to cut.

Your seam profile becomes your shop’s production standard. You build it once, refine it over time, and it pays off on every project that follows.

This guide explains how the values of a seam type work, how to set them up, and how to name seam types so they are easy to find.

A seam type has six values. Together they tell Fabricator how to handle one kind of edge: where to cut, what to mark, whether to make a reinforcement, and how that reinforcement meets the neighbouring edges.

Every value is measured from the drawn line: the edge of the wireframe as you modelled or measured it on the boat. A positive value is outward, away from the panel. A negative value is inward, into the panel. All values are in millimetres in a metric profile.

The values of a seam type, measured from the drawn line on one edge of a flat piece. This is the keder and zipper edge of example 9.

Cut offset is where the material is cut. This is not always where the finished edge ends up. A folded or hemmed edge needs extra material beyond the finished edge, so the cut goes further out. A bound or raw edge needs none, so the cut is where the finished edge will be.

Finish Cut offset
Raw or bound Where the finished edge is
Folded Where the finished edge is, plus the fold
Hemmed Where the finished edge is, plus the hem

Pen 1 offset is the main mark drawn on the cut piece, and the line the sewer works to. What it marks depends on the edge: on a reinforced edge, the inner edge of the reinforcement; on a folded edge with no reinforcement, the fold line; on a zipper edge, where the zipper tape goes. The rule: Pen 1 marks the line that matters most to the sewer.

Pen 2 offset is a second mark, for when Pen 1 is taken and another line is needed. The usual case is a reinforced zipper edge: Pen 1 marks the reinforcement, Pen 2 the zipper tape. Leave it empty when it is not needed, or when it would fall on Pen 1 or on the edge of the reinforcement.

Reinforce btm offset does two jobs. First, it sets how far this edge’s own reinforcement reaches toward the finished edge. Second, and just as important, it sets how far a neighbouring edge’s reinforcement runs along its side where it meets this edge. So Fabricator trims every reinforcement to size, including the sides where reinforcements of neighbouring edges meet, and the reinforcement comes off the cutter ready to use, with no measuring at the corners.

This value matters even on an edge that has no reinforcement of its own, because it still decides where the neighbour’s reinforcement stops. On a folded edge, consider making it about 3 mm smaller (the thickness of the fold), so that the reinforcement does not run into the fold.

Cut notch extension sets the depth of the alignment notches on the cut piece. Leave it at 0 unless the usual notch depth does not suit your material or process.

Reinforce, when on, makes Fabricator cut a reinforcement piece for this edge. It runs from the Pen 1 line (its inner edge) to the Reinforce btm offset (its outer edge), and it is cut as a piece of its own.

In Settings → Seam Types the six values are in this order: Cut offset, Pen 1 offset, Pen 2 offset, Reinforce btm offset, Cut notch extension and the Reinforce switch. An empty box means the value is not used.

The best way to see how the values work together is to go through real edges, from simple to complex. Each example says what the finished edge is, then gives the values that make it. In the tables, “empty” means the box is left empty.

The simplest edge. The material ends on the drawn line, the edge is left raw, and there is no reinforcement.

Cut offset Pen 1 offset Pen 2 offset Reinforce btm offset Cut notch extension Reinforce
0 empty empty 0 0 Off

Everything is zero or empty. The cut is on the drawn line.

Example 1: the cut line on the drawn line.

The finished edge is on the drawn line, but the fold needs 15 mm of extra material. Pen 1 marks the fold so the sewer knows where to fold.

Cut offset Pen 1 offset Pen 2 offset Reinforce btm offset Cut notch extension Reinforce
15 −15 empty −3 0 Off

Cut = 0 (the finished edge is on the drawn line) + 15 (the fold) = 15. Pen 1 at −15 marks the fold: the sewer folds the edge over to this mark. Reinforce btm offset −3 shortens a neighbouring reinforcement to allow for the fold. You can leave it at 0; try both in production and keep what you prefer.

Example 2: cut 15 mm out, the fold mark 15 mm in.

Example 3: reinforced edge, bound, 30 mm reinforcement

Section titled “Example 3: reinforced edge, bound, 30 mm reinforcement”

The finished edge is on the drawn line, with a 30 mm reinforcement and a binding tape. The binding wraps around the raw edge, so no extra material is needed. Pen 1 marks the inner edge of the reinforcement.

Cut offset Pen 1 offset Pen 2 offset Reinforce btm offset Cut notch extension Reinforce
0 −30 empty 0 0 On

Cut = 0: bound, so no extra material. Pen 1 = −30: the reinforcement reaches 30 mm in from the drawn line. Reinforce is on, so Fabricator makes the reinforcement piece.

Example 3: the reinforcement between Pen 1 and the drawn line.

Example 4: reinforced edge, folded, 30 mm reinforcement and 15 mm fold

Section titled “Example 4: reinforced edge, folded, 30 mm reinforcement and 15 mm fold”

As example 3, but folded instead of bound. The fold needs extra material. Pen 1 marks the inner edge of the reinforcement.

Cut offset Pen 1 offset Pen 2 offset Reinforce btm offset Cut notch extension Reinforce
15 −30 empty −3 0 On

Cut = 0 + 15 (the fold) = 15. Pen 1 = −30: the inner edge of the reinforcement, 30 mm from the drawn line. Reinforce btm offset = −3 shortens the reinforcement to allow for the fold. The reinforcement piece is 27 mm wide, but on the finished edge it comes close to 30 mm.

Example 4: the reinforcement stops 3 mm short of the drawn line, to leave room for the fold.

A keder sewn on the edge, with the material extending 20 mm beyond the drawn line. No pen line is needed: the keder is sewn right on the edge. Reinforce btm offset is 20, so that the reinforcements of neighbouring edges run out to this edge’s extension.

Cut offset Pen 1 offset Pen 2 offset Reinforce btm offset Cut notch extension Reinforce
20 empty empty 20 0 Off

Cut = 20: the extension, with no fold. Reinforce btm offset = 20: a neighbouring edge’s reinforcement runs 20 mm out, to match this edge’s extension.

Example 5: no reinforcement of its own, but the Reinforce btm offset tells the neighbours how far theirs reach.

A zipper sewn to a folded edge. The edge folds 20 mm, and the zipper tape lines up with the fold. Pen 1 marks the fold, which is also where the zipper tape goes.

Cut offset Pen 1 offset Pen 2 offset Reinforce btm offset Cut notch extension Reinforce
20 −20 empty −3 0 Off

Cut = 0 + 20 (the fold) = 20. Pen 1 = −20: the fold and the zipper tape, 20 mm in from the drawn line. Reinforce btm offset = −3, to allow for the fold.

Example 6: the fold mark is also the zipper mark.

Example 7: zipper 20 mm in, 30 mm reinforcement, 10 mm fold

Section titled “Example 7: zipper 20 mm in, 30 mm reinforcement, 10 mm fold”

A zipper whose teeth sit 20 mm in from the finished edge, with a 30 mm reinforcement and a 10 mm fold. Pen 1 marks the inner edge of the reinforcement. The zipper falls on the same line, so Pen 2 is not needed.

Cut offset Pen 1 offset Pen 2 offset Reinforce btm offset Cut notch extension Reinforce
10 −30 empty −3 0 On

Cut = 0 + 10 (the fold) = 10. Pen 1 = −30: the inner edge of the reinforcement, 30 mm in. With the teeth 20 mm in from the edge, the inner side of the zipper tape lands close to the same line, so it shares Pen 1 and no second mark is needed. Reinforce btm offset = −3, to allow for the fold.

Example 7: Zipper In20 R30 F10.

Example 8: zipper with a flap, reinforced, bound

Section titled “Example 8: zipper with a flap, reinforced, bound”

A zipper with a 30 mm flap of material beyond the drawn line, the teeth 30 mm in from the finished edge, a 70 mm reinforcement and a bound finish. The reinforcement runs from 30 mm outside the drawn line to 40 mm inside it. Pen 1 marks the inner edge of the reinforcement; Pen 2 marks the zipper tape, about 20 mm inside the drawn line depending on the zipper.

Cut offset Pen 1 offset Pen 2 offset Reinforce btm offset Cut notch extension Reinforce
30 −40 −20 30 0 On

Cut = 30: the extension; bound, so no extra material. Pen 1 = −40: the inner edge of the reinforcement, 70 mm in all minus the 30 mm outside. Pen 2 = −20: the zipper tape. Reinforce btm offset = 30: the reinforcement runs out to the finished edge.

Example 8: Zipper Ext30 In30 R70 B.

Example 9: keder and zipper, extended, inset, reinforced, folded

Section titled “Example 9: keder and zipper, extended, inset, reinforced, folded”

The full set-up: a keder and a zipper on one edge, extended 30 mm beyond the drawn line, the hardware 30 mm in from the finished edge, an 80 mm reinforcement and a 10 mm fold. A typical sprayhood track cover, where the material reaches over the track rail.

Cut offset Pen 1 offset Pen 2 offset Reinforce btm offset Cut notch extension Reinforce
40 −50 −40 27 0 On

Cut = 30 (the extension) + 10 (the fold) = 40. Pen 1 = −50: the inner edge of the reinforcement. Pen 2 = −40: the inner side of the zipper, about 40 mm from the keder groove when sewn correctly; your numbers may differ. Reinforce btm offset = 27: the 30 mm extension less about 3 mm for the fold.

Example 9: Keder Zipper Ext30 In30 R80 F10.
Seam type Cut offset Pen 1 offset Pen 2 offset Reinforce btm offset Cut notch extension Reinforce
Plain edge 0 empty empty 0 0 Off
Folded 15 mm 15 −15 empty −3 0 Off
Reinforced 30 mm, bound 0 −30 empty 0 0 On
Reinforced 30 mm, folded 15 mm 15 −30 empty −3 0 On
Keder, extended 20 mm 20 empty empty 20 0 Off
Zipper, folded 20 mm 20 −20 empty −3 0 Off
Zipper In20 R30 F10 10 −30 empty −3 0 On
Zipper Ext30 In30 R70 B 30 −40 −20 30 0 On
Keder Zipper Ext30 In30 R80 F10 40 −50 −40 27 0 On

Values in millimetres, measured from the drawn line: positive outward, negative inward. “Empty” means the box is left empty: the value is not used.

Once you know what the values do, name your seam types the same way every time. A good name lets you pick the right seam type from the list without opening it.

The name describes the finished result, not the values: where the edge ends up, what hardware is on it, and how it is finished. It has up to five parts, always in the same order. Leave out a part that does not apply; a missing part means the default: flush with the drawn line, no inset, no reinforcement, a raw edge.

Position Part What it says Example
1 Hardware What is on the edge, or what the edge is Edge, Keder, Zipper
2 Extension or shortening Where the finished edge is, from the drawn line Ext30, Sh20
3 Inset How far the hardware is from the finished edge In40
4 Reinforcement How wide the reinforcement is R40
5 Finish How the raw edge is finished F10, B

Hardware (position 1), always there. The first word says what is on the edge, or what the edge is, written out in full: Edge, Keder, Zipper, Keder Zipper, Seam. If your shop uses other hardware (Velcro, Snap, Lacing and so on), add your own words.

Extension or shortening (position 2). Where the finished edge is, measured from the drawn line: Ext beyond it, Sh behind it. This is where the edge ends up after folding or hemming, not the cut line. In millimetres. Leave it out when the edge is flush with the drawn line.

Inset (position 3). How far the hardware is from the finished edge, measured inward, whatever the extension or shortening. Leave it out when the hardware is on the edge. The inset is always measured from the finished edge, not the drawn line, so it is what you can measure on the finished piece.

Reinforcement (position 4). R and the whole width of the reinforcement in millimetres. Leave it out when there is none.

Finish (position 5). F for folded, with the fold; B for bound; H for hemmed, with the hem. Leave it out when the edge is left raw.

Read a name from left to right. Each part adds one thing; a missing part means the default.

Name Reads
Edge Plain edge, flush, raw
Edge F15 Plain edge, flush, folded 15 mm
Edge Ext20 F15 Plain edge, 20 mm beyond the drawn line, folded 15 mm
Edge R30 B Plain edge, flush, reinforced 30 mm, bound
Keder Keder on the edge, flush
Keder Ext20 Keder, finished edge 20 mm beyond the drawn line
Keder Sh15 Keder, finished edge 15 mm behind the drawn line
Zipper In20 Zipper, teeth 20 mm in from the finished edge
Zipper Ext30 In30 Zipper with a 30 mm flap, teeth 30 mm from the edge
Zipper Sh30 In30 Zipper, edge 30 mm behind the drawn line, teeth 30 mm from the edge (60 mm from the drawn line)
Zipper In20 R30 F10 Zipper, teeth 20 mm in, reinforced 30 mm, folded 10 mm
Keder Zipper Ext30 In30 R80 F10 Keder and zipper, edge 30 mm beyond the drawn line, hardware 30 mm in, reinforced 80 mm, folded 10 mm
Seam Plain seam between two panels
Seam R20 Seam between two panels, reinforced 20 mm

When you add a seam type, follow the order: hardware, extension or shortening, inset, reinforcement, finish. Use only the parts that apply, and the same abbreviations (Ext, Sh, In, R, F, B, H), so that names read the same across your shop and with other Fabricator users.

For a variation of a seam type you have, change only the number. If you have Keder Ext20 and need a 40 mm version, name it Keder Ext40.

For an edge with two kinds of hardware, write both words: Keder Zipper, not KZ or Keder/Zipper.

Each seam type also has a Description, for free notes on when and why to use it, for example “For sprayhood track covers, extends to hide the track rail”. Put there what does not belong in the name.

Abbreviation Means
Ext Finished edge beyond the drawn line (mm)
Sh Finished edge behind the drawn line (mm)
In Hardware inset from the finished edge (mm)
R Reinforcement width (mm)
F Fold (mm)
B Bound (binding tape)
H Hem (mm)
  • Name order: Hardware, Ext or Sh, In, R, F or B or H.
  • Left out means the default: flush, no inset, no reinforcement, raw edge.
  • Names describe the finished result: where the edge ends up, not where the material is cut.
  • In is measured from the finished edge, inward.
  • The values are measured from the drawn line: positive outward, negative inward.